Avance Solo Adapt Dressing Kit
Available Options
| BOX | Price | Quantity | Description | |
|---|---|---|---|---|
| BOX (5 Pcs) | Ex. GST : $420.80 Inc. GST : $462.88 |
Please note that product image is for reference only and may not represent the exact product.
Avance Solo Adapt NPWT System.
A portable, adapted version of Avance Solo, a single-patient-use negative pressure wound therapy system.
Key Features:
- Portable, discreet, and easy to operate
- Delivers consistent -125mmHg wound therapy without compromise
- Includes a 50ml canister for excess wound fluid to reduce the potential for the dressing to become saturated
- Battery-powered for an extended wear time up to 14 days
Clinical Benefits:
- The Avance Solo Adapt Negative Pressure Wound Therapy (NPWT) System is indicated for patients who would benefit from wound management via the application of negative pressure to promote wound healing through the removal of wound fluid.
- The Avance Solo Adapt NPWT System is indicated for removal of low to moderate amounts of wound fluid from Pressure Ulcers
- Supports management of Pressure Injuries and other wounds requiring negative pressure therapy.
- Enhances patient mobility and comfort with a lightweight, portable design.
The Avance Solo Adapt NPWT System is intended to be prescribed and used by healthcare professionals for therapy on adult patients in healthcare facilities and home care settings. It can be used by lay persons with training and ongoing supervision given by Healthcare Professionals. Avance Solo Adapt NPWT System dressings should only be applied and changed by your Healthcare Professional. If you are concerned about your wound, please contact your Healthcare Professional.
Precautions:
- Before starting therapy, evaluate the patient’s nutritional status and address severe malnutrition. Also consider the patient’s size and weight.
- Signs of possible infection or complications must be addressed immediately. Monitor the device, wound, surrounding skin, and patient status accordingly to ensure effective and safe treatment and patient comfort.
- For patients with ischemic condition or at application of a circumferential dressing, extra monitoring of wound status is required to avoid risk of compromised circulation.
- Avance Solo Adapt Pump is equipped with visual and audible notifications and alarms. Ensure that carrying or placement of the pump allows the user to detect audible and visual notifications and alarms.
- When Avance Solo Adapt Pump battery low alarm is triggered, replace the batteries in the pump. Only use the type and model of lithium batteries specified for this product by Mölnlycke Health Care, see section 8.
- Multiple layers of film or addition of an occlusive dressing over the Avance Solo Adapt Film may decrease the breathability, which may increase the risk of maceration.
- Application of certain skin protection products or using cleansing products prior to the application of Avance Solo Adapt Film, can affect the ability of the film to adhere securely
and create sufficient sealing. - Do not stretch Avance Solo Adapt Film since it may cause damage to the surrounding skin when negative pressure is applied.
- Do not use the products on patient and/or user with known hypersensitivity to the materials/components of the products.
- Ingrowth of tissue may occur if Avance Solo Adapt Foam is not changed in accordance with recommendations or as appropriate for the wound condition of the individual patient.
- Consider use of non-adherent wound contact layer to protect fragile tissue.
- Do not place Avance Solo Adapt Foam onto intact skin or non-protected superficial or retention sutures.
- Do not place Avance Solo Adapt Pump with canister in water or other liquids. Disconnect the pump and canister if ingress of water is observed.
- For daily hygiene routines do not expose Avance Solo Adapt Pump with canister or dressing to extensive contact with water.
- Avance Solo Adapt Foam and Avance Solo Adapt Film shall only be applied and changed by healthcare professional.
- No modification of this device (pump, canister, tubing, foam or film) outside these instructions for use is allowed as modifications may significantly compromise the ability of the system to deliver therapy.
- Do not disassemble Avance Solo Adapt Pump.
- Products in Avance Solo Adapt NPWT System shall only be used with products specified in Section 1, Product description.
- Do not cut the tubing or detach tubing from the canister.
- For CT scans and X-ray investigations, keep the pump out of the X-ray or scanner range. In the event that the pump is within a CT-scan or X-ray range, ensure to check that the pump functions correctly after the procedure.
- Avance Solo Adapt Pump is not intended for use aboard aircraft. Remove batteries during air travel.
- Avance Solo Adapt NPWT System products are provided sterile. Do not use if the sterile barrier is damaged or has been opened prior to use. Do not re-sterilize.
- Avance Solo Adapt Pump is for single patient use.
- Avance Solo Canister 50 ml, Avance Solo Adapt Foam, Avance Solo Adapt Film and Avance Solo Adapt Transfer Port are single use.
- Do not reuse Avance Solo Adapt NPWT System products. If reused, performance of the product may deteriorate and/or cross contamination may occur.
- Ensure that the battery lid on the Avance Solo Adapt Pump is closed during therapy.
- Always clamp the transfer port tubing and the canister tubing before disconnecting them.
For more information click below: